Pairing the energizer and remote control
The energizer and remote control must be set to the same address setting in order to communicate. The address setting is a number between 1 and 15.
To programme a connected energizer to communicate with a remote control, there are three steps:
Step 1 - Identify the energizer address (and/or change the address) using the mobile app
In the Home screen, scroll down and tap in the Energizer panel.
All energizers registered to the farm will be displayed.Tap on the energizer you want to use with the remote control.
Tap on Settings.
View the Current address.
💡 If necessary, click Change address and select a new address.
Step 2 - Set the remote control to match the energizer's address setting
On the remote control, press and hold
, then press
to enter the Setup menu.
Press
repeatedly until you get to the Address (Ad) option.
Press
repeatedly until you get to the matching address setting.
Press
. A moving arrow appears on the display.
After a few seconds, the remote control will switch off.
Step 3 - Test the energizer with the remote control
Make sure that the energizer is on and pulsing.
Press
to switch on the remote control.
Stand beside the energizer and press
.
The green light should flash to indicate that the energizer is in Standby mode.
Having problems?
If your energizer is frequently switching to Standby mode unexpectedly, a neighbour's remote control may be affecting your energizer. Change the energizer and remote control address settings to a new address.
If you have several remote-capable energizers on your farm, change the energizer and remote control address settings to match for ease of use.
If you have several remote-capable energizers on your farm and the remote control is controlling the wrong energizer, change each energizer to a unique address setting.
📝This will mean you need to go into the remote control Setup menu each time you want to control a different energizer.