Before you start, check that your 5000 indicator has been set up correctly for weighing, with the correct load bars selected.
You can check the Cell Code to make sure it matches the type of load bars or load cell you are using.
To check the Load Cell Settings:
From the Home screen, tap Settings, Next page, Next page then Service.
Enter the Password: 5000 then tap Log On:
Tap Load Cell.
On the Load Cell screen, check the Cell Code.
The code should match the brand of load bars being used:
Cell Code | Number of load bars or load cells | Load bars or load cells | Capacity (kg) | Capacity (lb) |
01 | 2 | Tru-Test SHD100 load bars | 4000 | 10000 |
02 | 1 | Tru-Test SHD100 load bars | 2000 | 5000 |
04 | 2 | Tru-Test HD5T load bars | 5000 | 11000 |
05 | 2 | Load bar (production testing) | 6500 | 14500 |
06 | 1 | Tru-Test HD5T load bar | 2500 | 5500 |
07 | 1 | Suspension cell | 5000 | 10000 |
08 | 1 | Suspension cell | 1000 | 2000 |
10 | 1 | Suspension cell | 250 | 500 |
12 | 1 | Produce platform 1.7 mV/V | 50 | 110 |
15 | 1 | Tru-Test personal platform | 150 | 300 |
17 | 1 | Suspension cell | 100 | 200 |
19 | 1 | Tru-Test Ezi-feet (1 foot) | 500 | 1000 |
21 | 4 | Tru-Test SHD100 load bars | 8000 | 17500 |
27 | 1 | Suspension cell | 10000 | 20000 |
29 | 2 | Tru-Test Ezi-feet (2 feet) | 1000 | 2000 |
39 | 3 | Tru-Test Ezi-feet (3 feet) | 1500 | 3000 |
44 | 2 | Tru-Test GP600 load bars | 1500 | 3300 |
49 | 4 | Tru-Test Ezi-feet (4 feet) | 2000 | 4400 |
66 | 1 | Tru-Test GP600 load bar | 750 | 1500 |
69 | 1 | Tru-Test XHD load cell (Kelba) | 4500 | 10000 |
70 | 1 | Suspension cell | 500 | 1000 |
79 | 1 | Tru-Test XHD2 load cell (AWT) | 4500 | 10000 |
80 | 1 | Suspension cell | 2500 | 5000 |
88 | 1 | Suspension cell | 50 | 100 |
89 | 1 | Tru-Test Extreme load cell (AWT) | 13600 | 30000 |
93 | 2 | Tru-Test MP600 load bars | 2000 | 5000 |
94 | 2 | Tru-Test MP/HD 800/1010 load bars | 3000 | 6600 |
95 | 1 | Tru-Test MP600 load bar | 1000 | 2000 |
96 | 1 | Tru-Test MP/HD 800/1010 load bar | 1500 | 3000 |
A4 | 2 | Digistar HD load bars | 3000 | 6600 |
A5 | 2 | Digistar 600 mm load bars | 1500 | 3300 |
A6 | 2 | Gallagher HD 1000 mm load bars | 3500 | 7700 |
A7 | 2 | Gallagher 600 mm and 1000 mm load bars | 2000 | 4400 |
A9 | 2 | Iconix 1000 mm steel load bars | 2000 | 4400 |
AA | 2 | Iconix HD 1000 mm steel load bars | 3000 | 6600 |
AB | 2 | Gallagher SHD 1000 mm load bars | 4500 | 9900
|
5. Return to the Weighing screen, zero the indicator and test the weigh scale using a known weight.
Having trouble?
If you are still having trouble or need advice, click on the Live Chat bubble in the bottom right-hand corner of this screen or email sf-support@datamars.com.